Industrial Process Chiller Systems from +90°C to -160°C
Such equipment as a process chiller is a potent industrial cooling system designed for heavy-duty, continuous operation. Its primary goal is to remove heat directly from machinery, manufacturing equipment, or chemical reactions and hold them at a stable setpoint, often well below ambient, to prevent overheating or uncontrolled processes related to it.
An industrial process chiller should not be confused with the chillers used for air conditioning of buildings. It is a machine that serves a production process, and that is why it has to keep the temperature within narrow tolerances and often work 24/7. On this page, we use the word “chiller” exactly in this meaning, as one more name for a process refrigeration machine. For example, MIRAI X CRYO chillers operate within a considerable temperature range from +90 °C (+194°F) to −160 °C (-256°F), and they can both cool and heat the heat transfer fluid.
How a Process Chiller Works
Process chiller units operate according to the following principle:
- At the first stage, a process chiller, with the help of the pump, sends cold water or glycol into heated machinery. The fluid absorbs the heat generated by the machine.
- The fluid, heated in such a way, goes back to the chiller and gets into its evaporator.
- The evaporator works as a heat exchanger: the warm fluid gives away its heat to the refrigerant, and because of this the refrigerant boils and becomes a low-pressure gas.
- Then the compressor increases the pressure and the temperature of this gas and directs it to the condenser. There the gas gives away its heat and becomes liquid again.
- At the final stage, the liquid refrigerant goes through an expansion valve where its pressure falls, and after that the refrigeration cycle is repeated once more.
As a result, the process fluid and the refrigerant each circulate in their own closed-loop circuit. At MIRAI INTEX®, we take a different route. In our MIRAI X CRYO cryochillers, a classic refrigeration cycle is replaced with an air cycle. It means that air (R729) is compressed and then expanded inside an oil-free turbo module, and after that the cold air cools down the heat transfer fluid with the help of a heat exchanger. Since the air does not change its phase during this cycle, such parts as an expansion valve or an evaporator in its classic form are simply not needed in the system. The process in our machines looks as follows:
- COMPRESSION. Air is compressed, which raises its pressure and temperature.
- HEAT EXCHANGE. The compressed air is cooled in a water-cooled heat exchanger.
- RECUPERATION. The air is cooled further in a recuperator, where it exchanges heat with the outgoing air.
- EXPANSION. The cooled air is expanded in a turbo expander, and its temperature drops drastically. This cold air is then used to cool either a chamber (in open-cycle machines) or a heat transfer fluid (in MIRAI X CRYO and other closed-cycle machines).
- RECIRCULATION. The air is reheated in the recuperator and then compressed again, and the cycle is repeated.
Types of Process Chillers
All process chillers can be divided into several categories by their key features. By the condenser type, they can be:
- an air-cooled process chiller (removing the heat with the help of fans that blow ambient air across the coils to push the heat out of the room);
- a water-cooled unit (cools the refrigerant that circulates in the system with the help of an external cooling tower).
By their compressor type, all process chillers are categorized as:
- Scroll;
- Screw;
- Centrifugal/turbocompressor;
- Reciprocating.
Lastly, by their temperature mode, they can be:
- A standard process chiller keeps the coolant (typically water) at +5 °C to +25 °C (+41 °F to +77 °F).
- A low-temperature or glycol process chiller operates at temperatures from 0 °C to −35 °C (+32 °F to −31 °F).
Process Chiller vs HVAC Chiller
What makes process chillers stand out from conventional HVAC chillers? The first and foremost difference is their purpose and operating mode. HVAC chillers are used for the maintenance of comfortable indoor temperatures, while process chillers remove heat from machinery, products, or chemical reactions and don’t allow them to overheat. Their temperature ranges also differ: the standard HVAC operational temperature range is from +6°C to +12°C, while process chillers cover a much wider range: from about +25 °C down to −35 °C with glycol, and down to −160 °C with cryogenic systems such as MIRAI X CRYO. That is why MIRAI INTEX machines do not belong to HVAC equipment. We do not produce chillers for air conditioning of buildings, and the word “chiller” on this page should be understood as a refrigeration machine for a certain process.
MIRAI X CRYO Industrial Process Chiller Units
Our process chiller series MIRAI X CRYO is designed for ultra-low temperature modes and uses air (R729) as a natural refrigerant. These closed-cycle cryochillers cool or heat the heat transfer fluid from +90 °C to −160 °C, with rated motor power up to 60 kW. As for the temperature stability, it is kept at the level of ±0.5 °C when the load is variable, and it becomes even better when the machine works in a steady mode. It is also worth mentioning that in 2024 MIRAI X CRYO was awarded at the RAC Cooling Industry Awards.
|
Model |
Rated motor power (kW) |
Heating capacity (kW) |
Dimensions (cm) |
|
MIRAI X CRYO 20 PRO |
20 |
12 |
130x94x180 |
|
MIRAI XS CRYO 20 |
20 |
9 |
60x160x178 |
|
MIRAI XM CRYO 20 |
20 |
18 |
60x160x178 |
|
MIRAI X CRYO 40 |
40 |
18 |
80x177x197 |
|
MIRAI X CRYO 60 |
60 |
18 |
80x177x197 |
The whole line covers the range from +90 °C to −160 °C (+194 °F to −256 °F). However, the exact temperature limits depend on a certain model, so we confirm them for your process at the stage of sizing.
Benefits of an Air Refrigerant Chiller System
Our engineering solutions for process chillers are based on air refrigerant technologies. They provide a range of valuable benefits as follows:
- Natural air as a refrigerant has a GWP of 0 and contains no F-gas. It means that your investment is protected, taking into account that the rules of HFC phase-down are getting stricter;
- The system is oil-free, and its operation is maintained with the help of special air bearings;
- Its partial load is maintained at levels from 10% to 100%.
- Besides, air is neither toxic nor flammable, and thanks to this the safety requirements on site become simpler.
Last but not least, the TCO of air refrigerant chiller systems is well balanced thanks to their energy efficiency, environmental friendliness, and high durability.
If we compare them with cascade vapor-compression systems, a single air-cycle machine is able to reach −160 °C, and there is no need to stack several refrigerant circuits for this. And if we compare them with liquid nitrogen cooling, you get rid of the necessity to buy LN2, store it and handle it on site.
Industrial Process Cooling Applications
Our process chillers find their application in those fields where a process requires very low temperatures or their precise control. Among them are the following:
- Pharmaceutical industry. In this field, our machines are used for storage of vaccines at ultra-low temperatures and in lyophilization of pharmaceutical products.
- Semiconductor fabrication. Here chillers are needed to keep process tools (for example, etch chambers) at stable temperatures, which are often below zero.
- Biobanking and research. Our machines cool storage rooms and biorepositories where biological samples are kept at ultra-low temperatures.
- Freeze drying. In industrial lyophilizers, the machines are used for cooling and heating of the shelves, as well as for cooling of the condenser.
Choosing the Right Process Chiller
When it comes to choosing the right process chiller, we recommend making your choice based on a couple of criteria. The first is the cooling capacity of a chiller. Then it is worth checking the operating temperature range and matching it with the cooling requirements of your industrial processes. One more thing to consider is the total cost of ownership (TCO), which is not limited to capital expenses but also includes maintenance and repair costs, possible modernization costs, electricity consumption costs, and engineering services.
Working with a Process Chiller Manufacturer
MIRAI INTEX is more than a supplier of process chillers. All our machines are designed and manufactured at our own facility in Brno, Czech Republic. The turbo module and the air bearings are also our own development; however, they are a part of the equipment and cannot be purchased as a separate product. Besides, please note that we have no machines that work only for heating: the ULT LIQUID COOLER product line provides cooling only, while the MIRAI X CRYO product line provides cooling together with heating. It means that you deal directly with the engineers who built your system, and the service is provided by the same team as well. Our manufacturing is certified to ISO 9001:2015. Our three product lines, ULT SPACE COOLER, ULT LIQUID COOLER and MIRAI X CRYO, are process chillers themselves. They are ready-made solutions for applications that require ultra-low temperatures, such as semiconductor manufacturing and pharmaceuticals.
As for manufacturers of conventional chillers, we can offer them the MIRAI Turbo 290 / 350, which is an oil-free propane (R290) turbocompressor with a capacity of 290–350 kW intended to be built into the chillers they produce. This is a separate product that does not belong to the MIRAI X CRYO line. Besides, there is also the MT 450 HP model that was presented at Chillventa 2026 and that can additionally work as a heat pump. More information about it will be available in the near future.
How does a process chiller system work?
Briefly speaking, it works as a closed loop: a cooling fluid (as a rule, water or a water-glycol mixture) goes through industrial equipment, takes its heat, and comes back to the chiller, where this heat is removed by a refrigeration cycle and rejected through the condenser, after which the pump supplies the cooled fluid to the machine again.
What are the main components of a process chiller?
The main components of a process chiller are the compressor, the condenser, an expansion valve (TXV or EEV) and the evaporator. Besides, there are also a pump, a fluid tank and a PLC controller in the system. As for MIRAI X CRYO cryochillers, an air cycle is used in them instead of such a circuit. It means that air is compressed and expanded by an oil-free turbo module that runs on air bearings, and the cold is transferred to the process fluid with the help of heat exchangers.
Why is precise cooling important for industrial processes?
Precise cooling contributes to stable product quality, control of chemical reactions, shortening of production cycles, and machinery lifespan enhancement. Besides, in pharmaceutical production, it contributes to GMP standards compliance.
What are the different types of process chillers?
By their condenser type, process chillers can be either air-cooled or water-cooled; by their compressor type, they can be scroll, screw, reciprocating, centrifugal or turbocompressor. By their cooling fluid type, they are divided into standard (water) and low-temperature (glycol or water-glycol mixture).
CTA: If you need a reliable process chiller for your manufacturing, please contact our sales team to get more information about MIRAI INTEX industrial solutions and get a quote.